Sign In | Join Free | My portofva.com
China Shenzhen Guangyang Zhongkang Technology Co., Ltd. logo
Shenzhen Guangyang Zhongkang Technology Co., Ltd.
Shenzhen Guangyang Zhongkang Technology Co., Ltd. Professional NLS Body Health Analyzer Machine Supplier Leading Technology for Low Level Laser Therapy
Active Member

10 Years

Home > Microcirculation Microscope >

Biochemical Analysis Microcirculation Microscope Blood Test Machine With Colorful LED Screen

Shenzhen Guangyang Zhongkang Technology Co., Ltd.

Biochemical Analysis Microcirculation Microscope Blood Test Machine With Colorful LED Screen

  • 1
  • 2

Brand Name : SSCH( Suyzeko)

Model Number : GY-880

Certification : CE

Place of Origin : China (Mainland)

MOQ : 1

Price : Negotiated

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 3000pcs per month

Delivery Time : 5-7 days after receiving payment

Packaging Details : carton box packing

Drawtube : colorful LED screen

Type : Biochemical Analysis System

Stage : X-Y double layer compound mechanical stage

Magnification : 400X

Warranty : one year

Microscope Package : Aluminum box

Built-in camera pixels : 380000 pixels

microcirculation LCD monitor : 16*12cm

Input&Output : AC input 100~240V 50/60Hz DC output DC12V,2A

Contact Now

Nailfold Capillary Microscopy Microcirculation Definition Blood Test Machine Microcirculation Microscope

What's micro circulation ?

The micro circulation is by blood, the lymph and tissue fluid flowing which directly participates in the organization, the cell matter, the energy, the information transmission . May directly observe the blood flows in the thin artery, the blood capillary, and the thin vein through the micro circulation microscope , but if it does not do the special handling is that cannot see clearly the lymph and tissue fluid mobile, therefore, on clinical usually thought the micro circulation refers to the blood micro circulation in the blood capillary .

Technical parameters:

Microscope Magnification ≥400 times
Built-in camera pixels 380000 pixels
Light source LED
Brightness of the light source ≥ 600cd/m2
Stage X-Y double layer compound mechanical stage
nailfold microcirculation microscope monitor colar LCD monitor 8inch(4:3)
Input&Output AC input 100~240V 50/60Hz DC output DC12V,2A
Microscope Package Aluminum box( Size 34*29*20cm)

Features:

1. in 5 seconds can be observed in the microvascular circulation, simple operation and fast;
2. the microscopic image is stable, clear, do not shake;
3. 400 times the microcirculation of a dedicated high-resolution lens of the microscope;
4. handheld ultra-light design, so that the observation of more mobility;
5. with micro-focus wheel, free to adjust the focus length, the use of more convenience
6. lens built-in LED cold light source, accurate projection illumination on an object;
7. using non-invasive way, to observe the microcirculation of human body in time;
8. observing the microcirculation for any part of human body.

Application:

1. nail wall distal microcirculation observation
2. cutaneous distal microcirculation observation
3. tongue microcirculation observation
4. the auricle distal microcirculation observation
5. lips microcirculation observation
6. the other parts of the microcirculation observed
7. sweat glands observed
8. hair follicles observed
9. bamboo charcoal commodity microcirculation efficiency testing
10.far- infrared commodity microcirculation efficiency testing
11. the germanium titanium micro-circulation of goods performance detection
12.ore commodity micro-cycle efficiency detection.

After has carried on the shape and the fluid state observation, but also should carry on the observation to the periphery condition:

1. Seeps out: refers to, in the blood vessel, appears the phenomenon for the blood plasma ingredient excessively permeability blood pipe wall and the accumulation in blood capillary’s periphery , is one of common micro circulation changes. Characteristic: The blood vessel ansa periphery gap expands, and bright; The blood vessel ansa’s image is fuzzy, the length reduces.

2. Hemorrhage: phenomenon for the red blood cell leaves to the blood vessel outside .

Should distinguish the hemorrhage which the flesh wound or other non- pathogenesis factor creates, if the leakage hemorrhage, the main reason is blood capillary wall damage, causes the permeability hyperfunction and the blood flow changes and so on .

Distributed pattern for finger nail fold blood capillary

The observation for nail fold micro circulation is mainly from three aspects ,including the shape, the fluid state and the blood vessel ansa perimeter.

Normal state: Nail fold blood capillary arrangement neat, distribution even, the blood vessel ansa is clearly discernible.

Abnormal state: Arrangement disorder, blood vessel ansa fuzzy, is possible to because of the oxygen deficit, the blood stream to be impeded, the Asian health and so on causes.

Shape of blood vessel ansa :

(1) Normal shape likes the hair clip , exceptionally for overlapping and abnormal, the overlapping proportion number should not surpass 30%, the abnormal should not surpass 10%.

(2) abnormal blood vessel:

Explained: 1st, the blood vessel of heart and brain disease, the diabetes, the desmosis and so on, with contract whole body disease or the partial fungus infection and flesh wound and other organization disease is easy to appear the blood vessel to be abnormal

2nd, when arteriosclerosis, diabetes with serious abnormal , and the proportion excessive highly.

3rd, collagen disease, Reynold sickness, neurosis, the variation of blood vessel increases.

Blood vessel ansa’s periphery

After has carried on the shape and the fluid state observation, but also should carry on the observation to the periphery condition:

1. Seeps out: refers to, in the blood vessel, appears the phenomenon for the blood plasma ingredient excessively permeability blood pipe wall and the accumulation in blood capillary’s periphery , is one of common micro circulation changes. Characteristic: The blood vessel ansa periphery gap expands, and bright; The blood vessel ansa’s image is fuzzy, the length reduces.

2. Hemorrhage: phenomenon for the red blood cell leaves to the blood vessel outside.

Should distinguish the hemorrhage which the flesh wound or other non- pathogenesis factor creates, if the leakage hemorrhage, the main reason is blood capillary wall damage, causes the permeability hyperfunction and the blood flow changes and so on.

Testing conditions:

1) Check the room temperature and humidity. Room temperature and humidity

should be kept relatively constant. room temperature should be maintained in the 22-24 degree , relative humidity about 70%

2) the patient generally take seats, keep the height of the hand the same with heart

3) Preparation of paraffin oil or cedar oil.Drop 2 drops in the nailfold skin. (Purpose prove light

transmission, and reduce skin scattering)

4)Testing generally be in the morning or afternoon, and review should at the same time every day.

5) the patient should

a.Avoiding intense activity or manual labor within one hour before testing

b. Take a rest about 15-30 minutes before testing

c.Can not take any drug which will affect the cardiovascular vessels before testing

d. Does not smoke , wash hands or eat within an hour before testing

e.Pay attention to the influence of the Female menstrual

Biochemical Analysis Microcirculation Microscope Blood Test Machine With Colorful LED Screen

Biochemical Analysis Microcirculation Microscope Blood Test Machine With Colorful LED Screen

Biochemical Analysis Microcirculation Microscope Blood Test Machine With Colorful LED Screen

Packaging & Shipping

  1. 1 pc/box. Deliver from Shenzhen, Guangdong.

  2. FedEx/DHL/UPS/TNT for samples, Door-to-Door;

  3. By Air or by Sea for batch goods, for FCL; Airport/ Port receiving;

  4. Customers specifying freight forwarders or negotiable shipping methods!

  5. Delivery Time: 2-5 days for samples; 5-7 days for bulk order.
    Normal packed by carton box, can be customized according to order quantity.

Service and Warranty


Guangyang Zhongkang Technology Co., Ltd is dedicated to providing innovative, quality products and excellent customer service. Whether you are placing an order, looking for technical support or just have a basic question, we will response to you within 24 hours and will strive to bring you the highest level of support. Please contact our company Service.

A. Warranty period
Our warranty includes the maintenance of material and manufacturing technology malfunctions within Thirteen months from the date you buy our machine.

B. Restriction
If the machine is not dated, we will be unable to provide you the service. We will not bear any responsibility if any damage caused by the followings: Damage caused by fire, earthquake, riots, or any force majeure.Incidental damage such as interruption of business and loss of business benefit including loss caused by using the machine, costs raised by any other machines’ replacement, installation and service, or claims of your customers.

C. Shipping problem
If you find there is something wrong while opening the packing, please contact shipping company at first time, both of us must discuss with relative shipping company to solve the problem. At the same time, we’ll do relative help for you.

Send your Inquiry Details in the Below, Click "Send" Now!

OEM Service Offered, Design Service Offered, Buyer Label Offered.


Product Tags:

capillary microscope

      

nail microscope

      
China Biochemical Analysis Microcirculation Microscope Blood Test Machine With Colorful LED Screen wholesale

Biochemical Analysis Microcirculation Microscope Blood Test Machine With Colorful LED Screen Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Guangyang Zhongkang Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 

Friendly Links: www.everychina.com

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

Copyright © 2009 - 2024 portofva.com. All rights reserved.